Ultrasonic Thickness Gauge
Model: TJ-UT210 · Brand SKU: TJT-UT-210
Dual-mode ultrasonic thickness gauge measuring 0.5–300 mm in steel, with auto-zero, continuous measurement and statistics for in-service pipe, vessel and steel structure inspection.
- Brand
- TJT Tester
- Model
- TJ-UT210
- Source
- In-house Made
- SKU
- TJT-UT-210
Learn more
Overview
The TJ-UT210 uses a dual-element pitch-and-catch probe arrangement for fast, stable readings. It is designed for in-service wall thickness and corrosion thinning monitoring of pipe, tanks, pressure vessels and steel structures.
The probe both transmits and receives, so readings stay stable even on rough surfaces without relying on couplant.
Main features
- Auto-zero calibration on contact
- Single point, continuous and multi-point statistics
- Upper and lower limit alarm thresholds
- Choice of straight, angle and small-radius probes
- Onboard data storage with USB export
Specifications
| Measuring range (steel) | 0.5 – 300 mm |
|---|---|
| Measuring range (aluminium) | 0.5 – 80 mm |
| Accuracy | ± 0.05 mm |
| Sound velocity range | 1000 – 15000 m/s |
| Probe frequency | 5 MHz / 10 MHz |
| Display | High-contrast LCD, readable indoors and out |
| Storage | ≥ 12000 measurements |
| Interface | USB |
| Weight | ≈ 0.4 kg |
| Battery | Built-in Li-ion, ≥ 12 h continuous use |
Key Features
- Dual-element pitch-and-catch probe
- 0.5–300 mm measuring range
- Auto-zero function
- Continuous measurement with min/max/average statistics
- Upper and lower limit alarms
- Built-in data storage and export
Applications
FAQ
Does the gauge need couplant?+
In dual-element mode the probe transmits and receives simultaneously, so no couplant is needed — simply place it on the surface. Single-element separated probes do require couplant for signal coupling.
Can I measure through a coating?+
Not for base metal thickness directly; you would need coating mode or to measure the coating first. Pairing the TJ-UT210 with the TJ-CT coating gauge allows combined coating and base metal measurement.